Compatibility in sewer camera gear means one thing here: the maker documents that two parts work together. A reel and a monitor, a sonde and a receiver, a head and a cable. This page shows those documented pairings and explains how they are judged. A connector that happens to fit is not the same as a supported pair, so the matrix stays strict about what counts as confirmed.
Compatibility statuses come from the PipeScope evaluation engine applied to verified configurations only. Manufacturer-verified range requires explicit manufacturer documentation.
Common diameters: 1.5, 2, 3, 4, and 6 inches (light bend scenario by default). Filter by pipe or bend difficulty via the form below.
| Configuration | 1.5 in | 2 in | 3 in | 4 in | 6 in |
|---|---|---|---|---|---|
|
Sanyipace S850DSTKM, 100 ftNo Locator |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Sanyipace S850DSTKM, 100 ftWith Locator |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Sanyipace S850DSTKM, 165 ftWith Locator |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Anysun, 100 ftCompact (17 mm) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (1.5" – 4" branch lines) |
|
VEVOR 100 ftBasic (7" Monitor) |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" straight runs) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
VEVOR 165 ft512 Hz Locator Kit |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
VEVOR WP9602B, 66 ftCompact (17 mm) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 4 in (1.5" – 3" branch lines) |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (1.5" – 3" branch lines) |
|
Holdwell S100, 100 ftWith 512Hz Locator Wand |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
VEVOR WP70, 100 ftWith 512Hz Locator Wand |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
FishPRO FP-100-17MM, 100 ftCompact 17mm Head |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 4 in (1.5" – 3" branch lines) |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (1.5" – 3" branch lines) |
|
Teslong NTS500, 50 ftCompact 12.5mm Head, Handheld 5" IPS |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 4 in (1.25" – 3" internal plumbing) |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (1.25" – 3" internal plumbing) |
|
Sanyipace S8417D, 100 ftCompact 17mm Head, Audio Mic |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (1.5" – 4" lateral lines) |
|
Forbest FB-PIC4188M, 130 ftWith 512Hz Locator Wand |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" commercial mains) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Sanyipace S810ADSMKT, 230 ftSelf-Leveling, Sonde, Heavy-Duty Frame |
Outside recommended range
Camera head 40 mm (~1.57 in) is too large for 1.5 in pipe |
Outside recommended range
Manufacturer straight-pipe range does not cover 2 in (4" – 12" municipal lines) |
Outside recommended range
Manufacturer straight-pipe range does not cover 3 in (4" – 12" municipal lines) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
RIDGID 70023 microDRAIN APXRIDGID 70023 microDRAIN APX, 65 ft |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 4 in (1.25" – 3" tight branch lines) |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (1.25" – 3" tight branch lines) |
|
Anysun SY-100FT-LOC-7IN |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Anysun SY-100FT-DVR-MC |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Anysun SY-100FT-1000TVL |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" drain lines) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Anysun SY-100FT-SL-LOC-9IN |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Anysun SY-150FT-SL-LOC-9IN |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Anysun SY-100FT-LOC-MC-9IN |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
VEVOR WP70-20M-512-WIFI |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Sanyipace S850DSTKM, 230 ft |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 8" commercial mains) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Sanyipace S850DSTKM, 230 ft |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 8" commercial mains) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Sanyipace S850DSTKM, 100 ft |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 4 in (1" – 3" small pipes) |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (1" – 3" small pipes) |
|
Eyoyo EY-100FT-7IN-DVR |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Holdwell HW-S-165FT-MC |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6" laterals) |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Holdwell S230, 230 ftWith 512Hz Locator Wand |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 8") |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
Sanyipace S850DSTKM, 100 ft |
Outside recommended range
Manufacturer straight-pipe range does not cover 1.5 in (2" – 6") |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 6 in |
|
RIDGID 70728 microREEL APXRIDGID 70728 microREEL, 100 ft |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (1.5" – 4") |
|
VEVOR WP9612FT, 165 ft9" Monitor |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (Straight pipes Φ 0.99-5.90 in / 25-150 mm) |
|
VEVOR WP9612FT, 165 ft10.1" Touchscreen |
Manufacturer-verified range
Manufacturer publishes pipe range covering 1.5 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 2 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 3 in |
Manufacturer-verified range
Manufacturer publishes pipe range covering 4 in |
Outside recommended range
Manufacturer straight-pipe range does not cover 6 in (Straight pipes Φ 0.99-5.90 in / 25-150 mm) |
|
Sanyipace S880, 165 ftSelf-Leveling, Sonde, Keyboard |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 1.5 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 2 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 3 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 4 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 6 in |
|
Sanyipace S880 / S58R, 165 ftWith 512Hz Locator Wand |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 1.5 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 2 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 3 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 4 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 6 in |
|
Sanyipace S5517DC, 66 ftCompact 18mm Head, 5" Screen |
Spec supported
OEM pipe range incomplete; 18 mm head is spec-supported for 1.5 in |
Spec supported
OEM pipe range incomplete; 18 mm head is spec-supported for 2 in |
Spec supported
OEM pipe range incomplete; 18 mm head is spec-supported for 3 in |
Spec supported
OEM pipe range incomplete; 18 mm head is spec-supported for 4 in |
Spec supported
OEM pipe range incomplete; 18 mm head is spec-supported for 6 in |
|
Anysun, 200 ftSelf-Leveling, Sonde, Wheeled Trolley |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 1.5 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 2 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 3 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 4 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 6 in |
|
Anysun, 300 ftWith 512Hz Locator, Wheeled Trolley |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 1.5 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 2 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 3 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 4 in |
Spec supported
OEM pipe range incomplete; 23 mm head is spec-supported for 6 in |
About this data
- How specs are verified: Each configuration is verified against manufacturer documentation and exact Amazon listing evidence. Missing or conflicting values are marked as not stated rather than inferred.
- Pipe range evidence: Pipe-range statements cite documented manufacturer specifications only. Ranges are never inferred from camera head diameter alone.
- Data verification: Latest configuration verification: Mar 1, 2026. Re-checked against manufacturer sources.
What counts as compatible
A pairing is treated as compatible only when the manufacturer states it. That is a higher bar than physical fit. Two parts can share a plug and still fail to work as a system, because firmware, signal, or power expectations differ. By recording only documented pairings, the matrix avoids the common trap of assuming that similar hardware must interoperate. Where the maker is silent, the pairing is marked unconfirmed rather than guessed.
Frequency match is not certification
Sondes and receivers raise a subtle case. A receiver that reads 512Hz will usually detect a 512Hz sonde, even across brands, because the frequency is the standard. That is a frequency match, and it is useful, but it is not the same as a maker certifying the pair. The matrix keeps the two ideas apart, so you can see when a pairing rests on a documented claim and when it rests on shared frequency alone.
Why exact configuration matters
Compatibility often depends on the precise configuration, not just the model name. A camera family may include versions with and without a locator, or reels of different lengths that share a name but differ in cable. A pairing verified for one configuration does not automatically transfer to another. The matrix ties each documented pairing to the exact configuration it applies to, so you match the version you actually own or plan to buy.
How to use the matrix
Start from the part you already have, then read across to what the maker documents alongside it. Treat a confirmed pairing as safe, a frequency match as likely but worth checking, and an unconfirmed cell as a question for the seller. Buying to a documented pairing removes guesswork, and it protects you from the disappointment of parts that fit mechanically but will not work together in the pipe.
When to confirm with the seller
Any time a pairing rests on frequency alone, or a cell is unconfirmed, ask before you rely on it. A short question to the seller costs nothing and saves a return. This is especially true when mixing parts across brands or across ranges, where a shared standard can carry you a long way but the exact behaviour still deserves a check.
Frequently asked questions
Does a matching connector mean two parts are compatible?
Not on its own. A shared connector is necessary but not sufficient, because signal, power, and firmware can still differ. Look for a documented pairing rather than trusting physical fit alone.
Will a 512Hz sonde work with any 512Hz receiver?
A matching 512 Hz frequency indicates signal-frequency compatibility. It does not by itself prove manufacturer-certified interoperability, equivalent locating depth, identical receiver behavior, or documented pairing.
Why is a pairing marked unconfirmed?
Because the maker has not documented it. That does not mean it fails, only that it is not proven. Treat an unconfirmed pairing as a question to resolve with the seller before you buy.